REVIEW Frequently asked questions about in vivo chlorophyll fluorescence: practical issues Hazem M. Kalaji • Gert Schansker • Richard J. Ladle • Vasilij Goltsev • Karolina Bosa • Suleyman I. Allakhverdiev • Marian Brestic • Filippo Bussotti • Angeles Calatayud • Piotr Dąbrowski • Nabil I. Elsheery • Lorenzo Ferroni • Lucia Guidi • Sander W. Hogewoning • Anjana Jajoo • Amarendra N. Misra • Sergio G. Nebauer • Simonetta Pancaldi • Consuelo Penella • DorothyBelle Poli • Martina Pollastrini • Zdzislawa B. Romanowska-Duda • Beata Rutkowska • João Serôdio • Kancherla Suresh • Wiesław Szulc • Eduardo Tambussi • Marcos Yanniccari • Marek Zivcak Received: 9 February 2014 / Accepted: 2 June 2014 / Published online: 15 August 2014 � The Author(s) 2014. This article is published with open access at Springerlink.com Abstract The aim of this educational review is to provide practical information on the hardware, methodology, and the hands on application of chlorophyll (Chl) a fluores- cence technology. We present the paper in a question and answer format like frequently asked questions. Although nearly all information on the application of Chl a fluores- cence can be found in the literature, it is not always easily accessible. This paper is primarily aimed at scientists who have some experience with the application of Chl a fluo- rescence but are still in the process of discovering what it all means and how it can be used. Topics discussed are (among other things) the kind of information that can be obtained using different fluorescence techniques, the interpretation of Chl a fluorescence signals, specific applications of these techniques, and practical advice on different subjects, such as on the length of dark adaptation before measurement of the Chl a fluorescence transient. The authors dedicate this paper to Professor Govindjee on the Occasion of his 80th Birthday H. M. Kalaji (&) Department of Plant Physiology, Faculty of Agriculture and Biology, Warsaw University of Life Sciences – SGGW, Nowoursynowska 159, 02-776 Warsaw, Poland e-mail: hazem@kalaji.pl G. Schansker (&) Avenue des Amazones 2, 1226 Chêne-Bougeries, Switzerland e-mail: gert.schansker@gmail.com R. J. Ladle Institute of Biological and Health Sciences, Federal University of Alagoas, Praça Afrânio Jorge, s/n, Prado, Maceió, AL, Brazil e-mail: richard.ladle@ouce.ox.ac.uk V. Goltsev Department of Biophysics and Radiobiology, Faculty of Biology, St. Kliment Ohridski University of Sofia, 8 Dr. Tzankov Blvd., 1164 Sofia, Bulgaria e-mail: goltsev@gmail.com; goltsev@biofac.uni-sofia.bg K. Bosa Department of Pomology, Faculty of Horticulture, Biotechnology and Landscape Architecture, Warsaw University of Life Sciences – SGGW, Nowoursynowska 159, 02-776 Warsaw, Poland e-mail: karolinabosa@gmail.com S. I. Allakhverdiev Institute of Plant Physiology, Russian Academy of Sciences, Botanicheskaya Street 35, Moscow 127276, Russia e-mail: suleyman.allakhverdiev@gmail.com S. I. Allakhverdiev Institute of Basic Biological Problems, Russian Academy of Sciences, Pushchino, Moscow Region 142290, Russia M. Brestic � M. Zivcak Department of Plant Physiology, Slovak Agricultural University, Tr. A. Hlinku 2, 949 76 Nitra, Slovak Republic e-mail: marian.brestic@uniag.sk M. Zivcak e-mail: marek.zivcak@uniag.sk F. Bussotti � M. Pollastrini Department of Agri-Food Production and Environmental Science (DISPAA), University of Florence, Piazzale delle Cascine 28, 50144 Florence, Italy e-mail: filippo.bussotti@unifi.it M. Pollastrini e-mail: martina.pollastrini@unifi.it 123 Photosynth Res (2014) 122:121–158 DOI 10.1007/s11120-014-0024-6 The paper also provides the physiological background for some of the applied procedures. It also serves as a source of reference for experienced scientists. Keywords Chlorophyll a fluorescence � Fluorescence imaging � Complementary techniques � Frequently asked questions � Plant stress monitoring � Photosynthesis Abbreviations An Net CO2 assimilation rate ATP synthase Enzyme responsible for the synthesis of ATP from ADP and inorganic phosphate Car Carotenoid Chl Chlorophyll Chlz Accessory chlorophyll in the photosystem II reaction center CP43, CP47 Core antenna proteins of PSII of 43 and 47 kDa Cyt b6/f Cytochrome b6/f complex D1 protein One of the major PSII reaction center proteins, the other being D2 DBMIB 2,5-Dibromo-3-methyl-6-isopropyl-p- benzoquinone DCMU 3-(3,4-Dichlorophenyl)-1,1- dimethylurea DF Delayed fluorescence ETC Electron transport chain ETR Electron transport rate FO Minimum Chl a fluorescence yield in the dark-adapted state FM Maximum Chl a fluorescence yield in the dark-adapted state Ft Fluorescence intensity at time t FV Maximum variable fluorescence, defined as FM - FO FV/FM A quantity related to the maximum quantum yield of PSII photochemistry FO/FM A parameter related to changes in heat dissipation in the photosystem II antenna FO 0, FV 0, FM 0, FS Minimum, variable, maximum and steady state fluorescence intensity in the light-adapted state Fq 0 FM 0–F0 [with F0 = Fs in the steady state] Fq 0/FM 0 Photosystem II operating efficiency Fd Ferredoxin FER Fluorescence excitation ratio FNR Ferredoxin-NADP?-reductase I1 Fluorescence intensity at 2–3 ms IRGA Infra red gas analyzer LED Light-emitting diode LHCII Light harvesting complex II NADP? Nicotinamide adenine dinucleotide phosphate, oxidized form NPQ Non-photochemical quenching, expressed as (FM/FM 0 - 1) OJIP transient Chl a fluorescence rise induced during a dark-to-strong light transition, where O is equivalent to FO, P is for peak, equivalent to FM (when measured at saturating light) and J and I are inflections between O and P A. Calatayud � C. Penella Departamento de Horticultura, Instituto Valenciano de Investigaciones Agrarias, Ctra. Moncada-Náquera Km 4.5, Moncada, 46113 Valencia, Spain e-mail: calatayud_ang@gva.es C. Penella e-mail: penella_con@gva.es P. Dąbrowski Department of Environmental Improvement, Faculty of Civil and Environmental Engineering, Warsaw University of Life Sciences – SGGW, Nowoursynowska 159, 02-776 Warsaw, Poland e-mail: piotr.andrzej.dabrowski@gmail.com N. I. Elsheery Agricultural Botany Department, Faculty of Agriculture, Tanta University, Tanta, Egypt e-mail: nshery@yahoo.com L. Ferroni � S. Pancaldi Department of Life Sciences and Biotechnologies, University of Ferrara, Corso Ercole I d’Este 32, 44121 Ferrara, Italy e-mail: frrlnz@unife.it S. Pancaldi e-mail: pcs@unife.it L. Guidi Department of Agriculture, Food and Environment, Via del Borghetto, 80, 56124 Pisa, Italy e-mail: lucia.guidi@unipi.it S. W. Hogewoning Plant Lighting BV, Veilingweg 46, 3981 PC Bunnik, The Netherlands e-mail: info@plantlighting.nl A. Jajoo School of Life Sciences, Devi Ahilya University, Indore 452 001, M.P, India e-mail: anjanajajoo@hotmail.com A. N. Misra Centre for Life Sciences, Central University of Jharkhand, Ratu- Lohardaga Road, Ranchi 835205, India e-mail: misraan@yahoo.co.uk; misra.amarendra@gmail.com 122 Photosynth Res (2014) 122:121–158 123 O (FO), K (FK), J (FJ), I (FI), P (FP) Fluorescence intensities at 20, 300 ls, 2–3 ms, *30 and *200 ms, respectively P680 Photosystem II reaction center chlorophyll dimer P700 Photosystem I reaction center chlorophyll dimer PAM Pulse amplitude modulation PFD Photon flux density PEA Photosynthesis efficiency analyser PIabs A JIP test parameter also called performance index PQ Plastoquinone PSI, PSII Photosystem I, Photosystem II QA Primary quinone electron acceptors of PSII QB Secondary quinone electron acceptor of PSII qE, qT, qI Non-photochemical quenching components defined by their relaxation times in darkness, where ‘‘E’’ stands for energy-dependent changes, ‘‘T’’ for state transitions, and ‘‘I’’ for photoinhibition qN Non-photochemical quenching, expressed as (1 - FV 0/FV) qP Photochemical quenching RLC Rapid light curve ROS Reactive oxygen species Rubisco Ribulose-1,5-bisphosphate carboxylase/oxygenase S-states S0 S1, S2, S3 and S4 Different redox states of the oxygen evolving complex Sm Normalized area above the OJIP transient STF Single turnover flash TL Thermoluminescence XC Xanthophyll cycle UV Ultraviolet DVIP Relative amplitude of the IP phase of Chl a fluorescence induction Uco2 Quantum yield of CO2 fixation UPSII PSII operating efficiency Introduction The measurement of chlorophyll (Chl) a fluorescence is one of the most widely used methods to probe photosynthesis (see Papageorgiou and Govindjee 2004 for reviews on application of Chl a fluorescence to different aspects of photosynthesis; also see Govindjee (2004) for an overview of important publications on Chl a fluorescence). Any researcher who tries to find his or her way in the fluorescence literature will initially be overwhelmed by the number of published articles and by all the conflicting ideas. Such a researcher will also quickly discover that it is not easy to find an answer for many simple and basic questions. We plan to fill this gap in this educational review focusing mainly on plants, green algae, and diatoms. The Chl a fluorescence signal is very rich in its content; it is very sensitive to changes in photosynthesis and can be recorded with great precision. Many processes affect the fluorescence yield and/or intensity, and using a variety of light protocols (flashes, pulses, continuous light, etc.), different processes can be studied. However, most authors have used only a limited set of experimental protocols based on methods that have been developed over time. S. G. Nebauer Departamento de Producción vegetal, Universitat Politècnica de València, C de Vera sn, 46022 Valencia, Spain e-mail: sergonne@bvg.upv.es D. Poli Department of Biology, Roanoke College, 221 College Lane, Salem, VA 24153, USA e-mail: poli@roanoke.edu Z. B. Romanowska-Duda Department of Ecophysiology and Plant Development, University of Lodz, Banacha 12/16, Lodz 90-237, Poland e-mail: romano@biol.uni.lodz.pl B. Rutkowska � W. Szulc Agricultural Chemistry Department, Faculty of Agriculture and Biology, Warsaw University of Life Sciences – SGGW, Nowoursynowska 159, 02-776 Warsaw, Poland e-mail: beata_rutkowska@sggw.pl W. Szulc e-mail: wieslaw_szulc@sggw.pl J. Serôdio Departamento de Biologia, CESAM – Centro de Estudos do Ambiente e do Mar, Universidade de Aveiro, Campus de Santiago, 3810-193 Aveiro, Portugal e-mail: jserodio@ua.pt K. Suresh Directorate of Oil Palm Research, West Godavari Dt., Pedavegi 534 450, Andhra Pradesh, India e-mail: sureshkancherla@rediffmail.com E. Tambussi � M. Yanniccari Institute of Plant Physiology, INFIVE (Universidad Nacional de La Plata – Consejo Nacional de Investigaciones Cientı́ficas y Técnicas), Diagonal 113 N�495, 327 La Plata, Argentina e-mail: tambussi35@yahoo.es M. Yanniccari e-mail: marcosyanniccari@conicet.gov.ar Photosynth Res (2014) 122:121–158 123 123 With the available commercial equipment, it is very easy to make a fluorescence measurement, but as the lit- erature shows, the interpretation of such measurements is still very contentious. There is not even agreement on the processes that determine the fluorescence rise from FO to FM, i.e., the variable fluorescence (FV). The dominant interpretation assumes that the variable fluorescence is determined by the redox state of QA, the first quinone acceptor of PSII, as originally proposed by Duysens and Sweers (1963) and recently defended by Stirbet and Gov- indjee (2012). Delosme (1967) on the other hand argued that QA was not enough and that there was another important process explaining part of FV. This position has recently been supported and extended by Schansker et al. (2011, 2014); see Question 21 for a broader discussion of this point. Another attractive feature of Chl a fluorescence is its non-invasive character, which allows the measurement on leaves and even on canopies of trees during long periods of time. A range of instruments has been developed focusing on different aspects of photosynthesis and on different properties of Chl a fluorescence. An overview will be given here of the available types of instruments, and we will discuss also what kind of information can be obtained with these instruments. It is important to understand that a fluorescence value by itself has no meaning. A well-defined reference state for the photosynthetic sample measured is needed to allow an appropriate interpretation of the data. Processes that relax following illumination will be discussed here as well as the time needed to reach the dark-adapted state, which is an important reference state. A widely read introductory paper on the use of Chl a fluorescence is by Maxwell and Johnson (2000), and two more recent papers treating the application of Chl a fluo- rescence techniques are by Logan et al. (2007) and Mur- chie and Lawson (2013). These papers focus on the analysis of what is called the steady state: the stable pho- tosynthetic activity after 5–10 min of illumination at a chosen light intensity. Here, our focus is broader, consid- ering a wider range of fluorescence techniques. We make the point that interpretation of fluorescence data can be improved making use, at the same time, of different classes of fluorescence techniques, as well as by the use of com- plementary techniques such as gas exchange and 820 nm transmission/absorption measurements. We also emphasize that there are still controversies with respect to the inter- pretation of Chl a fluorescence data. The educational review is meant to be a starting point for researchers interested in further exploiting Chl a fluo- rescence measurements to understand photosynthetic sys- tems. Some questions arise are trivial, e.g., Question 1: should the instrument be called fluorimeter or fluorometer? Both versions are allowed, the former being British-Eng- lish and the latter American-English. Answers to other questions may make the difference between a successful and a failed experiment. Question 2. Which types of instruments are available for fluorescence measurements? For a rough classification of fluorescence instruments used to probe electron transfer reactions involving photosystem II (PSII) and/or photosystem I (PSI), three major classes can be distinguished (see Fig. 1 for an illustration of this classification and see Question 33 for a discussion of fast repetition rate (FRR) measurements and equipment). [1] Instruments based on short light flashes (few ls or less). With such instruments, information on the electron transfer reactions within PSII can be obtained: re-oxidation kinetics of QA - via forward electron transfer to QB or recombination with the donor side of PSII (see Fig. 2). [2] Instruments based on a saturating pulse (few hundred ms strong light). With such instruments, information on the photosynthetic electron transport chain (ETC) can be obtained: reduction kinetics of the ETC, PSII antenna size, relative content of ETC components like PSI (see Fig. 3). [3] Instruments designed to study the steady state (relatively stable photosynthetic activity after 5–10 min of illumination). With such instruments, light-induced regulatory mechanisms, interaction between ETC, Calvin–Benson cycle, stomatal open- ing, and photorespiration (the process initiated when the enzyme Rubisco reacts with O2 instead of CO2) are studied (see Fig. 4). Flash fluorescence measurements Figure 2 shows an example of a typical flash fluorescence experiment. These measurements are based on the concept of a single turnover flash (STF). An STF has to meet two requirements: (1) The intensity of a STF must be high enough to excite the antennae of all PSII reaction centers (RCs) followed by a charge separation in all PSII RCs leading to a reduction of essentially all QA; (2) A STF must be short enough to induce only one charge separation in each PSII RC. In practice, this situation is never completely reached, and either misses or double hits are induced in a 124 Photosynth Res (2014) 122:121–158 123 small fraction of PSII RCs (see e.g., Kok et al. 1970; Shinkarev 2005). The re-oxidation of QA - can then be fol- lowed: in active RCs, most electrons will be transferred to QB and following a second flash to QB - (see Fig. 2). The first reaction has a half-time of 100–200 ls, and the second reaction has a half-time of 400–600 ls (reviewed by Pet- rouleas and Crofts 2005). If no PQ is bound to the QB-site, the electron on QA - has to wait, till a PQ molecule binds to the QB-site, and this process can take a few ms (Crofts and Wraight 1983). In the case of inactive PSII centers, forward electron transfer cannot take place, and re-oxidation of QA- occurs via a recombination reaction with the donor side of PSII (Lavergne 1982a; Chylla et al. 1987; Lavergne and Leci 1993; Schansker and Strasser 2005). These instruments can also be used to study the S-states (oxida- tion states S0, S1, S2, S3 and S4) of the oxygen evolving complex of PSII. A series of STFs induces period-4 oscillations in the FO-level as a function of the S-states (see Delosme 1972; Delrieu 1998; Ioannidis et al. 2000 for examples of such measurements). To probe the oxidation of reduced QA following a sat- urating flash, there are two possible approaches: (1) The easiest method makes use of low-intensity modulated light, which excites only a small fraction of the PSII RCs per unit of time. Figure 2 shows an example of such a measurement. For control samples, in which re-oxidation of QA - via forward electron Fig. 1 The processes that can be studied analyzing the fluorescence decay following a single turnover flash, the analysis of OJIP transients, or the quenching analysis. With the analysis of the fluorescence decay kinetics (STF analysis, purple line), it is possible to obtain information on electron transport reactions inside PSII and via the occupancy state of the QB-site on the PQ-pool redox state; OJIP transients (green line) can be used to obtain information on the redox state of the photosynthetic ETC, on the stoichiometry of the components of the ETC and on the relative PSII antenna size; the quenching analysis (rosa line) gives information on dynamic processes, electron flow, under steady state conditions, is sensitive to short-term regulatory processes in the antenna (see text) and to Calvin–Benson cycle activity, changes in photorespiration and stomatal opening (modified from Kalaji and Loboda 2010) Fig. 2 Example of the fluorescence decay kinetics following a single turnover xenon flash to a suspension of PSII-enriched membranes isolated from spinach. Several pre-flashes had been given to induce a partial reduction of the PQ-pool (G. Schansker, unpublished data) Photosynth Res (2014) 122:121–158 125 123 transport can occur, this approach works well. How- ever, when the sample is inhibited, e.g., by an electron transfer inhibitor such as DCMU (3-(3,4-dichloro- phenyl)-1,1-dimethylurea), which displaces QB from its binding site (Velthuys 1981; Lavergne 1982b), the low-intensity modulated light leads to the accumula- tion of a considerable population of QA - complicating the analysis of the experiment, because re-oxidation of QA - by recombination with the donor side is much slower than forward electron transport to QB. (2) The second method uses a combination of a STF followed by a probe flash that probes the redox state of QA at the time of the probe flash (this is called a pump– probe experiment) (Mauzerall 1972; Robinson and Crofts 1983). The intensity of the probe flash is much lower than that of the STF. In this case, the experiment is repeated many times and each time at a variable time t after the STF, a probe flash is given to probe the redox state of QA. In this way, the re-oxidation kinetics are constructed point by point. The actinic light problem, described above for DCMU inhibited samples, does not exist in this case.On the other hand, identical samples do not exist, and therefore, the biological variability between samples will lead to experimental noise and the need for repetitions to obtain smooth kinetics. To make different phases in the re-oxidation kinetics visible, the use of a logarithmic time scale has been introduced (see e.g., Cser and Vass 2007). Commercial equipment to make this type of measurements is the superhead fluorometers (Photon Systems Instruments, Brno, Czech Republic), which can also be used to measure OJIP transients and saturating pulse protocols (see below). Complementary techniques for flash fluorescence mea- surements are thermoluminescence (TL) (reviewed by Vass and Govindjee 1996; Misra et al. 2001a, b; Ducruet and Vass 2009) and delayed fluorescence (DF) (recently Fig. 3 OJIP transients (double normalized between O and P) measured on a bean leaf (Phaseolus vulgaris) shown on a linear timescale (a) and a logarithmic timescale (b). A measurement on dark adapted (closed symbols) which has an oxidized PQ-pool and a low J-step and a measurement made 5 s later (open symbols) where QA had become re-oxidized in part of the PSII RCs due to recombination (O level considerably below P), the PQ-pool is still almost completely reduced (J level near P), and the acceptor side of PSI is almost completely re-oxidized (I level close to that of the dark-adapted state) (G. Schansker, unpublished data) Fig. 4 Slow Chlorophyll a fluorescence kinetics (in arbitrary units) using a PAM-2100 fluorometer. The dark-adapted leaf is illuminated with weak modulated measuring light to give the zero fluorescence level F0. Application of a saturation pulse (SP) allows measurement of the maximum fluorescence level in the dark FM. Photosynthesis is then activated by an actinic light source (in this case 250 lmol photons m-2 s-1). SPs during the light phase were triggered spaced 1 min apart (indicated by arrows) to determine the maximum fluorescence intensity in the light (FM 0), and for each SP, qP, UPSII, and NPQ parameters were calculated, and these are indicated in the figure (Penella et al. unpublished data) 126 Photosynth Res (2014) 122:121–158 123 reviewed by Goltsev et al. 2009) measurements that pro- vide specific information on recombination reactions within PSII RCs. Flash fluorescence measurements are frequently used to study PSII mutants (e.g., Etienne et al. 1990; Nixon et al. 1991; Cser and Vass 2007) and can also be used in the case of treatments that affect the function of PSII [e.g., stresses like heat stress (Yamasaki et al. 2002)] or to probe the PQ redox state (Dannehl et al. 1996). Saturating pulse or OJIP measurements Upon a dark-to-light transition, the fluorescence intensity of a leaf or other photosynthetic samples increases from a low value (FO or O) via two intermediate steps (FJ or J and FI or I) in 200–300 ms to a maximum value (FM or P) during the application of a saturating pulse of light (see Fig. 3a, b; Strasser and Govindjee 1991; Strasser et al. 1995). The different fluorescence rise phases (OJ, JI and IP) can be related to different steps of the reduction of the ETC: OJ parallels the reduction of the acceptor side of PSII (QA ? QB); JI parallels the reduction of the PQ-pool and IP parallels the reduction of the electron transport acceptors in and around PSI (Schansker et al. 2005). This means that OJIP transients give information on the state of the ETC. Although complex simulations of OJIP transients use a kinetic model based on the gradual reduction of the ETC (see e.g., Lazár 2003; Zhu et al. 2005), it has been shown that the transients can also be approximated assuming that the transients consist of three kinetic components (Boisvert et al. 2006; Vredenberg 2008; Joly and Carpentier 2009) indicating that the rate limitations (exchange of PQ at the QB-site of PSII and re-oxidation of PQH2 by cyt b6/f) quite effectively separate the three rise phases kinetically. The kinetics of the OJIP transient are, e.g., sensitive to the PQ redox state (Tóth et al. 2007a) and PSI content (Oukarroum et al. 2009; Ceppi et al. 2012). During the isolation of thylakoid membranes, the properties of the ETC are modified, and this is reflected by changes in the fluores- cence kinetics. Attempts have been made (see e.g., Bukhov et al. 2003) to make the fluorescence induction kinetics of thylakoid membranes look more like those of leaves. Using a pulse-probe approach, a first pulse reduces the ETC and a second probe pulse given at time t after the first pulse probes the redox state of the ETC. The analysis of the regeneration kinetics of the OJIP transient gives informa- tion on the rate of re-oxidation of QA - by recombination with the donor side of PSII, the re-oxidation of the PQ-pool due to plastoquinol oxidase activity (see Question 17), and the rate of re-oxidation of the acceptor side of PSI in darkness (Schansker et al. 2005). Complementary techniques for OJIP measurements are 820 nm absorbance/transmission measurements that probe the redox state of PSI (plastocyanin, P700 and ferredoxin) and DF measurements that give information on the occurrence of recombination reactions in PSII as a function of the redox state of the ETC. The interpretation of these measurements can also be improved by determining the chl a/b ratio and the chl content of the leaves/cells. OJIP measurements have been used widely to study the effects of stress (see Questions 19, 24, 26–28). Steady state measurements The steady state refers to the relatively stable photosyn- thetic activity that is obtained when leaves or other pho- tosynthetic samples are illuminated at a chosen light intensity during approximately 5–10 min (or more). The Chl a fluorescence intensity in the steady state is affected both by the redox state of the ETC (and QA in particular) and by changes in the fluorescence yield, i.e., a change in the probability that absorbed light is emitted as Chl a fluorescence. These yield changes not only can be due to the formation of the transthylakoid DpH (Krause et al. 1983) and xanthophyll cycle (XC) related changes (Bilger and Björkman 1991), antenna size changes—for example, due to state transitions, which are especially obvious for algae such as Chlamydomonas reinhardtii (see e.g., Iwai et al. 2008)—or photoinhibition (see e.g., Björkman and Demmig 1987; Van Wijk and Krause 1991; Tyystjärvi and Aro 1996) but are also due to the activation of ferredoxin NADP?-reductase (FNR) on the acceptor side of PSI (Schansker et al. 2006, 2008). In the 1980s, an analysis was developed, called the quenching analysis (see Question 15 for a more detailed discussion of the quenching analysis) that can distinguish between redox changes (photochemical quenching) and fluorescence yield changes. A fluorescence yield change occurs when the rate constant for either fluorescence or heat emission changes. If this leads to a smaller FM value (and in many cases smaller FO value), this is called non-photochemical quenching. Figure 4 gives an example of such a protocol. Just as in the case of the flash fluorescence measurements (see above), the fluores- cence intensity is probed using low-intensity modulated light. The steady state is induced using continuous actinic light of a chosen intensity, and in addition every 100 or 200 s (this can be variable time interval), a saturating pulse (comparable to an OJIP transient) is given to reduce the ETC and all QA. On turning off the actinic light, relaxation of the induced non-photochemical quenching can be fol- lowed using saturating light pulses to probe changes in the FM level. In general, three relaxation phases are observed (Demmig and Winter 1988; Horton and Hague 1988): the qE which relaxes within 100–200 s as a consequence of the dissipation of the transmembrane DpH, the qT, whose relaxation is complete within 15 min and the qI which Photosynth Res (2014) 122:121–158 127 123 covers all processes that need more than 15 min to recover. As will be discussed later in detail (see Question 15) the qT and qI are less well defined. It is worth mentioning here that by measuring Chl a fluorescence induced by the sat- urating pulses with a higher time resolution (i.e., measuring OJIPs), it is possible to obtain more information on the character of the qT and qI phases (Schansker et al. 2006). The relaxation of the different non-photochemical quenching phases can be treated as the sum of three exponentials (see e.g., Walters and Horton 1991; Roháček 2010; and Question 15). Obtaining the ‘maximum’ FM 0 value is not a trivial issue. Markgraf and Berry (1990) and Earl and Ennahli (2004) observed that in the steady state, high light intensities are needed to induce the maximum FM 0 value. Earl and Ennahli (2004) observed that more than 7,500 lmol photons m-2 s-1 (the maximum intensity of their light source) were needed to reach the maximum FM 0 value of their maize leaves and that at higher actinic light intensities, more light was needed to saturate FM 0. Schansker et al. (2006) observed the same actinic light intensity dependence measuring both fluorescence and 820 nm transmission and suggested that the ferredoxin/thioredoxin system that is thought to continu- ously adjust the activity of several Calvin–Benson cycle enzymes (see Question 6), is responsible for the actinic light intensity dependence. Earl and Ennahli (2004) proposed an extrapolation method based on the measurement of FM 0 at two light intensities to obtain the true FM 0 value. Loriaux et al. (2013) studied the same light intensity dependence of FM 0 and proposed the use of a single multiphase flash lasting approximately 1 s to determine the maximum FM 0 value. This flash consists of two high light intensity phases sepa- rated by a short interval at a lower light intensity during which the fluorescence intensity decreases. The second high light intensity phase of this protocol has a higher light intensity than the first phase (see also Harbinson 2013 for a commentary on this paper). Complementary techniques for this type of fluorescence measurement are gas exchange measurements (to probe Cal- vin–Benson cycle activity, stomatal opening, CO2 conduc- tance) and 820 nm absorbance/transmission measurements. 77 K fluorescence spectra Low temperature (77 K) fluorescence measurements repre- sent another technique to obtain information on the photo- systems. At room temperature, variable fluorescence is emitted nearly exclusively by PSII. Byrdin et al. (2000) detected only a small difference in the quenching efficiencies of P700 and P700? at room temperature. This is supported by the observation that inhibiting PSII by DCMU (Tóth et al. 2005a) or cyt b6/f by DBMIB (Schansker et al. 2005) does not affect FM despite a big difference in the redox state of P700 in the absence and presence of inhibitors. However, variable fluorescence emitted by PSI can be induced on lowering the temperature to 77 K. Although measurements of light-induced fluorescence changes can be made at 77 K, in most cases, the fluorescence emission spectrum (600–800 nm) is measured. This type of measurement is used to obtain information on the PSII and PSI antennae. A common application of 77 K measurements is the detection of the occurrence of state transitions (e.g., Bellafiore et al. 2005; Papageorgiou and Govindjee 2011; Drop et al. 2014), where changes in the relative amplitudes of the PSII and PSI bands are indicators for this process. Figure 5 gives an example of a measured 77 K spectrum. Emission bands at 685 and 695 nm are related to the antenna of PSII, and peaks around 730 nm are related to the antenna of PSI (Govindjee 1995; Špunda et al. 1997; Srivastava et al. 1999). Complementary techniques are ultrafast femto- or picosecond absorbance or fluorescence measurements that give information on energy transfer within the antenna (e.g., Gilmore et al. 1998; Richter et al. 1999) but which are beyond the scope of this educational review. Fast fluorescence techniques (ns, ps, fs time range) As noted in the previous paragraph, fast fluorescence (and absorption) techniques, which probe energy transfer between chlorophylls or between carotenoids and chloro- phylls in the photosynthetic antennae and the charge Fig. 5 77 K fluorescence emission spectra of leaves of plants grown hydroponically on a complete medium (black line) and on medium containing only traces of sulfate (green line). Sulfate deficiency led to extensive chlorosis and in addition to a rather specific loss of PSI. This reduced the long wavelength bands around 730 nm and increased the 685 and 695 bands due to a decreased re-absorption by PSI reaction centers of Chl a fluorescence emitted by PSII (Schansker and Ceppi, unpublished data) 128 Photosynth Res (2014) 122:121–158 123 separation processes in the RCs of PSII and PSI will not be discussed in this paper. See e.g., Holzwarth (1996, 2008) and Berera et al. (2009) for introductory reviews on the application of these methods. Question 3. What is the effect of wavelengths at which the fluorescence is measured on the character of the fluorescence signal? Most commercial instruments measure Chl a fluorescence at wavelengths longer than 700 nm. At room temperature, at wavelengths longer than 700 nm, PSI becomes an important source of fluorescence emission. As shown by Genty et al. (1990) and Pfündel (1998) in C3 plants, about 30 % of the FO emission is due to PSI fluorescence, and in C4 plants, this percentage is even higher (Pfündel 1998). This causes, e.g., a systematic underestimation of the FV 0/ FM 0 value, which is used as a measure of the maximum quantum yield of PSII. Detecting Chl a fluorescence emission at wavelengths below 700 nm can considerably reduce this problem. However, in measuring equipment such as photosynthetic efficiency analyser (PEA) and HandyPEA instruments (Hansatech Instruments Ltd, UK) which use red LEDs with an emission peak around 650 nm, this would have led to an overlap between the actinic wavelengths and the detecting wavelengths. With the introduction of (strong) LEDs emitting at shorter wave- lengths, e.g., in the blue (see e.g., Nedbal et al. 1999), it is now technically possible to avoid this overlap and to detect fluorescence below 700 nm. Interference of PSI fluores- cence at wavelengths longer than 700 nm should be taken into account especially when measuring fluorescence parameters in the light-adapted state. Non-photochemical quenching induced in the light quenches the variable fluorescence (FM–FO) to a larger extent than FO fluores- cence. This makes the underestimation of the true FV 0/FM 0 value light intensity dependent as well, since a higher light intensity induces more non-photochemical quenching. Question 4. Which part of the leaf is probed and analyzed by a fluorescence measurement? The leaf is optically complex. In a dorsiventral leaf, the palisade parenchyma cells have been shown to act as light guides, keeping the light more or less focused (Vogelmann and Martin 1993; Vogelmann et al. 1996). The lobed cells of the spongy mesophyll and the spaces that surround these cells, on the other hand, disperse the light (Vogelmann and Martin 1993). At the same time, there is a strong light gradient within the leaf (Vogelmann 1989, 1993). This means that the light intensity decreases rapidly as light penetrates into the leaf. As a consequence, illuminating and probing Chl a fluorescence emission on the adaxial surface of the leaf, chloroplasts located deep in the leaf will be excited by a much lower photon flux density than those located close to the adaxial side of the leaf (Terashima and Saeki 1985; Fukshansky and Martinez von Remisowsky 1992). At the same time, the spectral distribution of the light changes as well: as light penetrates the mesophyll, the relative contribution of green and far-red (FR) light pro- gressively increases, because the absorption of these wavelengths by the leaf is less efficient (Sun et al. 1998; Rappaport et al. 2007). The chloroplasts located deeper in the leaf, i.e., those of the spongy tissue, acclimate to these lower, FR-enriched light intensities by increasing the antenna size of PSII, reducing the number of RCs, and decreasing the PSI/PSII ratio (Terashima et al. 1986; Evans 1999; Fey et al. 2005; Pantaleoni et al. 2009). Since the emitted fluorescence is a linear function of the light intensity (Vogelmann and Evans 2002; cf. Schansker et al. 2006), chloroplasts located deeper in the leaf will con- tribute to a lesser extent to the detected fluorescence signal. In practice, fluorescence measurements will probe mainly chloroplasts in the palisade parenchyma cells (Vogelmann and Evans 2002). The assumption that not all chloroplasts are assayed is supported by the observation that a fivefold decrease in the chlorophyll content of the leaf does not affect the detected FO and FM values (Dinç et al. 2012). In fact, since the total amount of fluorescence emitted by the leaf does not change, it suggests that the light beam probes deeper in the leaf as more chlorophyll is lost. The optical properties of the leaf also mean that measurements made on the abaxial (bottom) side of the leaf have characteristics that differ considerably from those made on the adaxial (top) side of the leaf (Schreiber et al. 1977). Oxygen and CO2 assimilation measurements on the other hand assay the whole leaf, and this may lead to deviations when com- paring, for example, measurements of the oxygen evolving activity with fluorescence measurements (Björkman and Demmig 1987; Tyystjärvi and Aro 1996). Given the gradient of photosynthetic properties that exists within the leaf (Terashima et al. 1986; Evans 1999), the photosynthetic response of a leaf depends on the wavelength composition of the exciting light. Deeper penetrating green light probes more low light acclimated chloroplasts located in the lower cell layers than blue light that is strongly absorbed by the leaf and mainly probes chloroplasts close to the adaxial side of the leaf. Question 5. How to dark-adapt leaves? For the interpretation of Chl a fluorescence measurements, it is important that the state of the photosynthetic apparatus Photosynth Res (2014) 122:121–158 129 123 at the beginning of the measurement is well defined. The dark-adapted state of the leaf is a well-defined state of the photosynthetic apparatus and, therefore, for most experi- ments, photosynthetic samples are first dark adapted. There are four main methods to achieve dark adaptation in leaves: 1. In the case of an intact plant, a leaf can be put into a leaf clip shielding it from ambient light. However, if the ambient light intensity is high, and the leaf is not entirely flat, there is a chance that some stray light reaches the shielded area. 2. Detached leaves can be kept for a while between wet filter paper in darkness and subsequently measured in the laboratory. Detachment of leaves has consequences for the physiological state of the leaf: it causes, for example, a closure of the stomata (Raschke 1970). See Potvin (1985) and Weng et al. (2011) for a comparison of the properties of attached and detached leaves and Kato et al. (2002) for a discussion of the differences between leaves and leaf disks. 3. Under laboratory conditions, measurements can be made in the dark or in a dimly lit room under conditions that induce very little photosynthetic activ- ity. Traditionally, low-intensity green light has been used as a kind of safe light (see Sun et al. 1998 for a discussion of this point) although we note that leaves can still absorb and use most of the green light for photosynthesis (cf. Sun et al. 1998; Vogelmann and Evans 2002; Rappaport et al. 2007). 4. Loss of time for dark adaptation can be avoided when the measurements are made directly in the field at night (no need for leaf clips). In this case, the leaves are allowed to dark adapt for many hours, and the results of such measurements differ from measurements on leaves following a relatively short dark-adaptation period during the day. Question 6. What is a ‘‘good’’ dark-adaptation time? Dark adaptation of samples that will be used for Chl a fluorescence measurements, is often associated with the re-oxidation of QA -. However, dark adaptation is a con- siderably more complicated process, and there are more factors that can affect a subsequent fluorescence measurement. In dark-adapted leaves, several enzymes are inactivated to prevent wasteful reactions. Examples of such enzymes include Rubisco (e.g., Streusand and Portis 1987); four other thioredoxin-dependent enzymes: D-fructose1,6-bis- phosphatase, phosphoribulokinase, and sedoheptulose-1, 7-bisphosphatase (Buchanan 1984; Scheibe 1990) and ATP synthase (Stumpp et al. 1999); and FNR (Carillo et al. 1981; Satoh 1981). These enzymes are active in the light, and during a light-to-dark transition, they gradually become inactive again. The half-time of inactivation of Rubisco under in vivo conditions is 2–4 min (Stitt et al. 1987; Laisk and Oja 1998). Inactivation of ATP synthase and the three other Calvin–Benson cycle enzymes is under control of the thioredoxin system (Scheibe 1990), and their inactivation depends on the re-oxidation of stromal com- ponents such as ferredoxin and NADPH. FNR inactivation varies depending on the species: pea leaves need *15 min for full inactivation (Schansker et al. 2006), whereas in a Pinus species, an hour is needed (Schansker et al. 2008). Once inactivated, all of these enzymes must first be acti- vated again before steady state photosynthesis is induced, and this affects the fluorescence induction kinetics (see Papageorgiou et al. 2007; Papageorgiou and Govindjee 2011 for an in-depth discussion of the fluorescence kinetics beyond P or FM in a variety of photosynthetic organisms). In addition, active FNR (i.e., an activated acceptor side of PSI) has an effect on the IP phase of the OJIP transients and on the amplitude of the FM that can be reached by a strong pulse of light (Schansker et al. 2008). In most fluorescence studies, many are not interested in the pro- cesses mentioned above, and in that case, it is best to make the dark-adaptation time long enough to allow at least FNR to become inactive again (a marker for this is a regenera- tion of the fluorescence IP phase and in addition a regen- eration of 820 nm re-reduction phase paralleling the IP phase, see Schansker et al. 2006, 2008). As mentioned in Question 2 Sect. 3, several regulatory and stress-related processes that affect the fluorescence yield (quench FM) are induced in the light. Following a light-to-dark transition, i.e., on turning off the light, these processes are reversed. State transitions (the transfer of a part of the antenna system among PSII and PSI) and XC related processes may take a considerable amount of time to reverse (Fork and Satoh 1986; Ruban and Horton 1999) and the recovery of a plant from photoinhibition takes hours (Havaux 1989; Long et al. 1994). An answer to the question as to what a good dark- adaptation time is, depends on the information we want to obtain. If the aim is the study of the regulatory and pho- toinhibition-related processes, a dark-adaptation time of 15 min that allows FNR (at least in plants like pea) to become inactive again would be sufficient. If someone is interested in long term adaptation responses of a leaf or other photosynthetic organism to a treatment, much longer dark-adaption times that allow also the regulatory pro- cesses and processes like photoinhibition to recover may be considered (see also the next question). 130 Photosynth Res (2014) 122:121–158 123 Question 7. How to obtain the best reference FO and FM values for the quenching analysis? In field experiments, predawn measurements are often used to obtain reference FO and FM values for measurements made during the day (Logan et al. 1999; Maxwell and Johnson 2000; Demmig-Adams et al. 2006). Under these conditions, NPQ is assumed to be completely relaxed and therefore zero, and the photoinhibition induced during the previous day is expected to have been reversed (Flexas et al. 1998; Logan et al. 1999; Demmig-Adams et al. 2006). However, in some cases, chronic photoinhibition occurs, which can be easily detected by lowered predawn FV/FM values (Osmond and Grace 1995; for a review see Dem- mig-Adams et al. 2012). We note that the absence of light during recovery experiments may prevent a full repair of photoinhibitory (Greer et al. 1986) and heat stress damage (Tóth et al. 2005b). Light is needed for the synthesis of ATP, which is needed for the synthesis of the D1 protein (Kuroda et al. 1992). Edhofer et al. (1998) have reported that light is needed for translation elongation of the D1 protein; these are processes that are part of the PSII repair cycle following damage to PSII (recently reviewed by Nixon et al. 2010). Low-intensity actinic light generates the ATP needed for the PSII repair cycle, and at the same time, it does not induce additional photoinhibition and is thereby more effective than a complete dark recovery (see e.g., Elsheery et al. 2007). Question 8. What can go wrong during a fluorescence measurement on leaves? Technical issues To dark-adapt leaves in the field, leaf clips have been developed. They cover the area of the leaf to be measured. The measuring head of, for example, a HandyPEA can be connected to a leaf clip, after which the clip can be opened, and the measurement made. Since such measurements are normally evaluated afterward, it should be kept in mind that unopened or partially opened leaf clips are a common reason for transients showing no or little fluorescence rise. A smooth leaf can also lead to problems, since the clip may shift while attaching the measuring head, and in that case, a non-dark-adapted part of the leaf will be measured. If the leaf is not flat, some stray light may enter the leaf clip via the spaces left between the leaf clip and the leaf surface. Especially on a bright day, this may prevent a full dark adaptation of the covered leaf area. The same problems can occur with pulse amplitude modulated (PAM) type instruments developed for field applications, which use leaf clips to allow dark adaptation. When working with a PAM instrument, the measuring light intensity must be chosen in such a way that the FM stays within the measuring window. If the measured signal is too strong, then the highest values will be cut off. For example, as a rule of thumb the fluorescence intensity induced by the measuring light (associated with FO) should be approximately 10 % of the total scale. In any case, absolute values and their limits depend on the manufac- turer, and its instructions should be carefully read before starting any measurements. Further, the distance between the leaf and the fiber optics has to be adjusted; it is usually set between 1 and 1.5 cm. Background fluorescence signals from the environment must be suppressed by zeroing the signal in the absence of a leaf sample. Using direct fluorescence equipment like the Handy- PEA, there is also a risk that the emitted fluorescence intensity causes an overload of the detector. It is therefore important to check if, at a given gain and excitation light intensity, the measured fluorescence kinetics remain below the maximum measurable fluorescence intensity. If the emitted fluorescence intensity is too strong, then the top part of the transient will be cut off, and in that case, the gain has to be reduced. Question 9. Why was it so difficult to determine the FO before ~1985? It may be hard to imagine nowadays, but the determination of a correct FO value was a major problem for researchers using Chl a fluorescence up to the mid-1980s (see Kalaji et al. 2012a, b for a historical overview of instrument development). The shutters used at the time had a full opening time of anywhere between 0.8 ms (e.g., Neubauer and Schreiber 1987) and 2 ms. At high light intensities, the J-step is reached after *0.8–2 ms of illumination. To minimize the effect of the shutter opening time, in many studies, low-intensity light was used to slow down the fluorescence induction kinetics. In the 1980s, two funda- mentally different solutions for the shutter problem were introduced in the form of modulated systems (Schreiber et al. 1986) and PEA-type instruments (Strasser and Gov- indjee 1991). These two measuring concepts are explained and compared in Questions 10 and 11. Question 10. What is the principle of modulated fluorescence measurements? Modulated systems, pulse amplitude modulated fluorome- ters, (PAM) use a trick to separate the effect of the actinic light that drives photosynthesis and the low-intensity measuring light that is used to probe the state of the pho- tosynthetic system on the measured fluorescence intensity (see also Question 2 Sect. 3). A so-called lock in amplifier Photosynth Res (2014) 122:121–158 131 123 only registers the fluorescence changes induced by the modulated measuring light and ignores the fluorescence changes induced by the continuous actinic light. This way the low-intensity measuring light can be used to measure both the FO (induced by the measuring light itself) and FM (induced by a strong light pulse) values (Schreiber et al. 1986). The effective light intensity of modulated light depends on the pulse frequency. In the case of a modern PAM instrument, the modulated measuring light consists of 1–3 ls flashes of red or white light, and flash frequencies between 100 and 20,000 Hz can be chosen. At the lowest frequency, the effective photosynthetic photon flux density is \0.2 lmol photons m-2 s-1; an intensity that is 200 times higher when the highest frequency is chosen. The choice of a low frequency gives not only a very small actinic effect (= measuring-light-induced FV) but also a relatively poor signal-to-noise ratio. A high frequency not only is considerably more actinic but gives also a much better signal-to-noise ratio. The actinic effect of the mea- suring light becomes especially visible (and problematic) if PSII electron transfer inhibitors such as DCMU are being used (see Question 2 Sect. 1). Compared to PEA-type instruments an advantage of the modulated fluorimeters is that the measured fluorescence yield is independent of the intensity of both the actinic light and light of the saturating pulse (Schreiber et al. 1986). In the case of PEA-type instruments, the measured fluorescence intensity is a linear function of the actinic light intensity used, and as a con- sequence, the measured fluorescence intensities must be normalized first (e.g., divided by the light intensity) before measurements made at different light intensities can be compared (see e.g., Schansker et al. 2006). Question 11. What is the principle of direct fluorescence measurements? In the so-called direct fluorescence instruments-i.e., instruments in which the actinic light that drives photo- synthesis is also used as measuring light-the FO problem is solved by using strong light emitting diodes (LEDs): light sources that can be switched on/off very quickly (Strasser and Govindjee 1991). In modern equipment, a stable light intensity emitted by the LEDs is reached in less than 10 ls. Initially, only red (650 nm) LEDs were available for this type of measurement but now colors like other orange (discussed by Oxborough 2004), green (Rappaport et al. 2007), and blue (Nedbal et al. 1999) or a mix of LEDs of different colors (Schreiber 1998) are also available. In the original PEA instrument, the response time of the LEDs was still in the order of the 40–50 ls (e.g., Strasser et al. 1995) necessitating the use of extrapolation to estimate the FO value; in the current instruments, a response time of 10–20 ls is good enough for an accurate determination of the FO value for light intensities below *10,000 lmol photons m-2 s-1 (cf. Schansker et al. 2006). The absence of a measuring light source means that between pulses, there is true darkness. As a consequence, the FO can be determined more accurately than in the case of a modulated system (see Schansker and Strasser 2005 for a discussion on the effects of very low light intensities on the FO value). The absence of measuring light is particularly advanta- geous when the samples to be analyzed have been inhibited with electron transfer inhibitor such as DCMU. Another important difference between PEA instruments and mod- ulated PAM instruments is the data sampling strategy. In PEA instruments, the data sampling is non-linear. In HandyPEA instruments, during the first 300 ls of illumi- nation one measuring point is collected every 10 ls; between 300 ls and 3 ms one point per 100 ls, between 3 and 30 ms one point per ms, and between 30 and 300 ms one point per 10 ms. In this way, an OJIP transient mea- sured at a high time resolution is defined by approximately 120 measuring points. In the case of a PAM instrument, a measurement with the same initial time resolution would yield at least 20,000 measuring points (for 200 ms). This makes the HandyPEA files much easier to handle when analyzing them using spreadsheet programs like Microsoft Excel. Question 12. Why use a logarithmic timescale to visualize fluorescence transient measurements? As described above, PEA instruments allow a shutter-less measurement of OJIP transients. However, PEA instru- ments make use of a second innovation and that is the use of a logarithmic timescale to visualize the measurements of the OJIP fluorescence rise (Strasser and Govindjee 1991). Bannister and Rice (1968) had already used this idea more than 20 years earlier, but at that time, it was not picked up by others. The logarithmic timescale was later exploited by researchers measuring fluorescence relaxation following a STF, as well (see Question 2 Sect. 1; e.g., Cser and Vass 2007). The logarithmic time scale distorts the time dependence somewhat but, at the same time, allows the visualization of considerably more kinetic features than is possible on a linear time scale. This additional kinetic detail makes it much easier to detect changes in the fluo- rescence kinetics. Fluorescence measurements shown on a linear timescale are always dominated by the slower changes (see Fig. 3a). A logarithmic timescale turns exponential rise phases into sigmoidal rise phases, and we must keep in mind that the sigmoidicity of the fluorescence rise cannot be derived on the basis of fluorescence tran- sients visualized on a logarithmic timescale. 132 Photosynth Res (2014) 122:121–158 123 Question 13. Direct or modulated fluorescence? It is possible to measure OJIP transients using a modulated system (Schreiber 1986; Neubauer and Schreiber 1987; Schreiber and Neubauer 1987), and at the same time, it is possible to make a quenching analysis (see Questions 2.3 and 15) using a PEA-type instrument (Schansker et al. 2006). However, modulated instruments are much better suited for a quenching analysis, and PEA-type instruments are the instruments of choice for a study of the OJIP kinetics. Thus, we recommend that both must be used to get a complete picture. Question 14. What kind of additional information can be obtained using fluorescence imaging? All the instruments, discussed thus far, integrate the signal of the measured area. Fluorescence imaging permits the study of spatial heterogeneities in the fluorescence emis- sion intensity within cells, leaves, or whole plants; heter- ogeneities caused by a range of internal plant factors (Gorbe and Calatayud 2012). It can also be used to average and analyze the fluorescence signal from much larger leaf areas than classical methods would allow, and at the same time, it allows the simultaneous measurement/screening of many samples/mutants in, for example, a microwell plate or of colonies grown on a Petri dish (see e.g., Niyogi et al. 1997; Serôdio et al. 2012) or all the leaves of an rosette of Arabidopsis. There are several commercial imaging instruments on the market. It is a technique whose devel- opment has kept pace with improvements in LED tech- nology. For reliable imaging measurements, it is critical that the whole sample area be illuminated homogeneously. Several introductory texts and reviews have been published on fluorescence imaging (e.g., Buschmann et al. 2001; Oxborough 2004; Lenk et al. 2007; Scholes and Rolfe 2009). Since it was not possible to image FO 0 with the imaging systems available in the late 1990s, Oxborough and Baker (1997) derived an equation to estimate it: FO 0 ¼ FO FV FM þ FO FM 0 : This equation allows the calculation of the parameters qP [=(FM 0 - FS)/(FM 0 - FO 0)] and FV 0/FM 0. The challenge using fluorescence imaging is to process all the data col- lected in a scientifically meaningful way. Meyer and Genty (1998) analyzed their data making frequency distributions of parameters of interest; we recommend that this method is considered for future experiments. Imaging can be used, e.g., to assess the dynamics and heterogeneous behavior of stomatal opening/closure over a leaf, a phenomenon also called stomatal patchiness. A palette of false colors is used to cover the range of fluo- rescence intensities (normalized between 0 and 1), assigning a color to each pixel of the image (Gorbe and Calatayud 2012). Based on the image, different areas of the leaf can be chosen, the associated fluorescence data aver- aged, fluorescence parameters can be calculated, and sub- sequently, the photosynthetic properties of the chosen area can be studied. Using fluorescence imaging, it is easy to detect photo- synthetic heterogeneities in a leaf (Meyer and Genty 1998) and to follow how any stress affects the leaf in spatial terms. In a popular early experiment, the imaging tech- nique was used to show the gradual infiltration of PSII inhibiting herbicides in the leaf (e.g., Daley et al. 1989; Lichtenthaler et al. 1997; Chaerle et al. 2003) or the effect of reactive oxygen species (ROS)-inducing herbicides (e.g., Hideg and Schreiber 2007). Spatial heterogeneities that have been studied using fluorescence imaging include heterogeneities occurring during the following processes: induction of photosynthesis (Genty and Meyer 1995; Daley et al. 1989), the onset of senescence (Wingler et al. 2004), chilling (Hogewoning and Harbinson 2007), the response to drought (Woo et al. 2008), nutrient stress (Landi et al. 2013), ozone stress (Gielen et al. 2006; Guidi et al. 2007), wounding (Quilliam et al. 2006), and during infection with viruses (Balachandran et al. 1994) or fungi (Guidi et al. 2007). Several studies, using imaging to study Chl a fluo- rescence parameters under various conditions (high/low ambient CO2 concentration, high/low light intensity, etc.), have yielded information on the relationship between leaf structure and organization on the one hand and the response to stress conditions on the other (Baker 2008; Roháček et al. 2008; Guidi and Degl’Innocenti 2011; Gorbe and Calatayud 2012). Serôdio et al. (2013) have introduced, a new application of fluorescence-imaging systems, which allows the rapid generation of light-response curves (see Question 18) simultaneously illuminating replicates of samples using spatially separated beams of actinic light of different intensities. Question 15. What kind of information can be obtained using the quenching analysis (see Question 2)? In leaves exposed to a certain irradiance, the fluorescence intensity is affected by changes both in the redox state of the ETC (particularly the redox state of QA) and in the fluorescence yield due to light-induced changes in the properties of the PSII antenna. A method called the quenching analysis was developed to separate these two types of process. In most cases, the quenching analysis is used to describe the steady state, i.e., the stable Photosynth Res (2014) 122:121–158 133 123 photosynthetic activity, which is usually reached after approximately 5–10 min of illumination at a chosen actinic light intensity. A protocol was developed (Schreiber et al. 1986; Fig. 4) based among others on the work of Bradbury and Baker (1981) in which the measurements are initiated by switching on the measuring light to determine the FO value of a dark-adapted sample. A saturating light pulse is then applied to determine the FM. The measurement is contin- ued switching on an actinic light source to induce photo- synthesis, until the fluorescence emission stabilizes at a level called FS. The FM 0 is then determined by applying another strong pulse of light followed some time later (e.g., 10 s) by turning off the actinic light. Turning off, the actinic light will cause a quick, partial, re-oxidation of the photosynthetic ETC. Within the first 100 ms of darkness, the PQ-pool will be largely re-oxidized by forward electron transport toward PC? and P700?, and a value close to FO 0 can be measured. The FO 0 level subsequently increases again due to non-photochemical reduction of the PQ-pool by NADPH and possibly Fdred (Mano et al. 1995; Gotoh et al. 2010; Guidi and Degl’Innocenti 2012). This so-called ‘‘FO 0 rise’’ can be almost completely suppressed by a short pulse of FR light (e.g., of 1 s duration) following the turning off of the actinic light. The increase of the fluo- rescence intensity from FS to FM 0 is related to a change in the redox state of the ETC, whereas the difference between FM 0 and the dark-adapted FM is then a measure of the fluorescence yield change, which in the case of qE is associated with increased heat dissipation. In quenching analysis terminology, this approach splits the fluorescence changes into a photochemical quenching (redox related) and a non-photochemical quenching (fluorescence yield related) part. On turning off the actinic light, the relaxation of the non-photochemical quenching, i.e., the increase of FM 0 to FM, can be followed and several contributing pro- cesses can be resolved (Walters and Horton 1991; Roháček 2010). Schreiber et al. (1986) introduced the parameter qN = 1 - FV 0/FV to quantify changes in the non-photo- chemical quenching. The parameter qN can range between 0 and 1, and for its calculation, the FO 0 value is needed. In 1990, Bilger and Björkman (1990) introduced the param- eter NPQ = FM/FM 0 - 1 which has as advantages over the parameter qN that its range is not restricted (see Question 21), and in addition, it is not necessary to know the FO 0 value. However, Holzwarth et al. (2013) evaluating the parameter NPQ, concluded that in this treatment of the fluorescence data, the relationship between the quenching parameter and the underlying processes becomes distorted, especially when the time dependence of NPQ is considered. For the analysis of the relaxation kinetics of the parameter qN semi-logarithmic plots of Log(qN) versus time are made. This linearizes the slowest component. Using linear regression, the decay half-time and amplitude of this component can be determined. This component (an exponential function) can then be subtracted from the ori- ginal data, and a new semi-logarithmic plot can be made of the remaining qN. The procedure can then be repeated (e.g., Walters and Horton 1991; for a discussion of the theoretical basis of the resolution method, see Roháček 2010). The least controversial of these kinetic processes is the process relaxing during the first 100–200 s of darkness, with a relaxation half-time of *30 s. In quenching analysis terms, this is called the qE or high-energy quenching; it depends on a low lumen pH and is affected by the XC (reviewed by Horton et al. 1996; Müller et al. 2001; Gil- more 2004; Krause and Jahns 2004; Ballottari et al. 2012). However, the exact mechanism of the induction of the qE and the exact components involved in this process are still a hotly debated issue (e.g., Caffari et al. 2011; Johnson et al. 2011; Miloslavina et al. 2011). A set of mutants has been generated playing an important role in the study of the qE, in which different components and processes related to qE have been modified (Niyogi et al. 1998). The second process, the qT, with a half-time of 5–10 min has been assigned to state II to state I transitions (transfer of LHCII units from PSI to PSII) based on the observation that it was already induced at low light intensities (Demmig and Winter 1988) and on its possible sensitivity to the phos- phatase inhibitor NaF (Horton and Hague 1988). Schansker et al. (2006) studying the kinetics of the saturating pulses showed that the main fluorescence change occurring in this time interval in pea leaves is the regeneration of the IP phase suggesting that the qT reflects the inactivation of the acceptor side of PSI (the inactivation of FNR). Other processes that have been associated with the qT are some slowly relaxing component(s) of qE (Lokstein et al. 1993; Joliot and Finazzi 2010) and light-dependent movements of chloroplasts (Cazzaniga et al. 2013). In practice, there are several arguments making it doubtful that the qT is a reliable measure for state transitions. The slowest relaxa- tion phase, the qI, which may last several hours can consist of several processes: photoinhibition of PSII and XC related changes (reviewed by Krause and Jahns 2004) and possibly also state II to state I transitions (Schansker et al. 2006) if a change in the JI amplitude is related to state transitions as suggested by Schreiber et al. (1995) for cyanobacteria. It should be noted that the rate with which these processes reverse in darkness is not necessarily the same in all photosynthetic organisms. For example, the regeneration of the IP phase parallels the qT phase in pea leaves (Schansker et al. 2006), and it is complete within 15 min, whereas the same process in needles of Pinus halepensis takes 1 h (Schansker et al. 2008). 134 Photosynth Res (2014) 122:121–158 123 Question 16. Why is far-red light used to determine the FO and FO 0 values? For leaves, it is reasonable to assume that under most conditions, nearly all PSII RCs are in the open state (QA oxidized) following dark adaptation. However, the assumption is not true for heat-stressed leaves (Ducruet 1999; Tóth et al. 2007b) and leaves that show a high rate of chlororespiration. Chlororespiration refers to the non-pho- tochemical reduction of the plastoquinone pool by reducing equivalents derived from Fdred or NADPH in the stroma (Bennoun 2002). Feild et al. (1998) showed a high chlo- rorespiratory activity in light acclimated sunflower leaves following a light-to-dark transition leading to considerably higher FO 0 values. This FO 0 increase is due to a population of reduced QA associated with a more reduced PQ pool. There is redox interaction between the PQ-pool and QA leading to a redox-equilibrium (Diner 1977); for pea leaves, it was shown that a completely reduced PQ-pool (induced by anaerobiosis) is in equilibrium with reduced QA in 20 % of the PSII RCs (Tóth et al. 2007a). To assure maximum oxidation of the PQ pool, the leaf can be pre-illuminated with FR light. For this purpose, FR light in the 720–735 nm range is normally used. FR light preferentially excites PSI and thereby causes an oxidation of the PQ pool. We note that FR light can induce charge separations in PSII (Pettai et al. 2005; Schansker and Strasser 2005). Pettai et al. (2005) demonstrated that FR light at 740 nm still induces a low level of oxygen evolu- tion even though the activity is three times less than that induced by FR light at 720 nm. In practice, FR light induces about 2.5 % of FV associated with QB - in 50 % of the RCs (Schansker and Strasser 2005). However, this observation is only of importance for direct fluorescence measurements, since the effects induced by FR light are also induced by the measuring beam of a modulated fluo- rescence instrument. A short FR pulse (*1 s, at *720–735 nm) given to a light-adapted leaf has two main effects: (i) it re-oxidizes the PQ-pool within 100 ms and (ii) it suppresses the tran- sient FO 0 increase, which is normally observed following a light-to-dark transition (Mano et al. 1995; Gotoh et al. 2010; Guidi and Degl’Innocenti 2012). It is related to non- photochemical reduction of the PQ-pool by NADPH or Fdred; this process is mediated by an enzyme complex called NADPH dehydrogenase (NDH) (Burrows et al. 1998). The induction of the qE component of non-photo- chemical quenching leads to a quenching of the FM level and in many plant species to a quenching of the FO 0 level as well (Bilger and Schreiber 1986; Bilger and Björkman 1991; Noctor et al. 1991). This qE quenching relaxes quickly in darkness. To determine the associated FO 0 quenching accurately, the FO 0 level must be determined immediately after turning off the actinic light. The non- photochemical reduction of the PQ-pool affects the FO 0 level as well, and this may complicate an accurate deter- mination of the extent of FO 0 quenching. Since the non- photochemical reduction of the PQ-pool is a rather slow process peaking approx. 40 s after turning off the light (Burrows et al. 1998), and the maximum re-oxidation of the PQ-pool following lights off takes less than 100 ms (Ceppi 2010), the FO 0 level can be determined quite accurately before the transient non-photochemical reduc- tion of the PQ-pool sets in. However, using *1 s of FR is the most straightforward approach to obtain an oxidized PQ pool. Question 17. How can the NPQ index be calculated when NPQ is formed in the dark? As noted in Question 16, a process called chlororespiration has been identified in higher plants (Bennoun 1982, 2002; Rumeau et al. 2007). Cyanobacteria, which are thought to be the ancestors of the chloroplast, lack mitochondria; instead they have a respiratory chain that shares the PQ- pool with the photosynthetic ETC (Vermaas 2001; Sch- metterer and Pils 2004; Hart et al. 2005). It allows the creation of a pH gradient over the thylakoid membrane in the dark, and this gradient is utilized to synthesize ATP. In the dark, the respiratory activity in cyanobacteria is con- siderably higher than in higher plants. In fact, chlorore- spiration in higher plants is seen as a rudiment of the original respiratory chain. Also in green algae, the respi- ratory chain is still quite active (see Beardall et al. 2003 for a discussion of this topic). Another group of organisms that have been shown to have a high chlororespiratory activity are some microalgae, including diatoms (e.g., Caron et al. 1987). As a consequence, there is no complete relaxation of qE in the dark. XC activity in dark grown diatoms occurs as a result of the acidification of the thylakoid lumen due to this chlororespiratory activity (Jakob et al. 1999). One effect of this high chlororespiratory activity in diatoms is that the FM level of dark-adapted diatoms is lower than the FM 0 observed under low actinic light (Cruz et al. 2010). This means that it is not possible to apply the commonly used NPQ equation: NPQ ¼ FM FM 0 � 1; ð1Þ since the calculated value would be negative [FM \ FM 0]. A practical solution for this problem is the determination of the light-response curve (see Question 18) and to replace FM by the maximum FM 0 level measured (FM 0 max; Serôdio et al. 2006) in Eq (1): So, Photosynth Res (2014) 122:121–158 135 123 NPQ ¼ F0Mmax FM 0 � 1: ð2Þ In this way, NPQ values will always be positive and approach a minimum value close to zero under conditions closely corresponding to a state with a very small trans- thylakoid proton gradient. Question 18. Can the time that is needed for a complete quenching analysis be shortened? To characterize the properties of parameters such as qP, UPSII [= (FM 0 - FS 0)/FM 0] and NPQ, it is common practice to determine the light intensity dependence of these parameters (see e.g., Bilger and Björkman 1991; Gray et al. 1996; Verhoeven et al. 1997). The classical approach is to illuminate the leaf at each light intensity, until steady state is reached (see Questions 2.3 and 10). This process can be quite time-consuming, especially if the fluorescence quenching analysis is performed for field experiments. To reduce the time needed for this type of measurement, a faster procedure was developed and called rapid light curves (RLCs) (White and Critchley 1999; Ralph and Gademann 2005). RLCs can be used to study the physio- logical flexibility of the photochemistry in response to rapid changes in irradiation (Guarini and Moritz 2009). Such changes occur frequently in natural environments. An RLC is a plot of the electron transport rate (ETR: UPSII 9 PFD 9 0.5 9 leaf absorptivity coefficient) as a function of the actinic light intensity, which is applied for fixed short-time periods (e.g., 10 s or 1 min). Here, PFD stands for photon flux density, and here, it is assumed that the PSI:PSII ratio is 1:1. However, this is only a rough approximation and the real ratio will differ between sam- ples (see Question 26). For this type of analysis, two cri- teria are important: (1) the samples must be dark adapted, and (2) photosynthesis must be induced [activation of the Calvin–Benson cycle enzymes that become inactive during incubation in darkness (see Question 6)] before the mea- surement sequence is started (White and Critchley 1999). Dark adaptation of the samples allows the determination of the reference FO and FM values needed for the calculation of qN and/or NPQ. If light-adapted samples are used for the experiments, for which reference FO and FM values are missing, then the effective quantum yield (UPSII) and ETR can still be calculated, but not the non-photochemical quenching parameters, nor qP. In other words, the best protocol consists of a dark acclimation of the sample, a weak modulated beam and a saturating pulse to determine the reference FO and FM, respectively, and then a pre- illumination with a moderate light intensity (approx. 50 % of the ambient light intensity applied for several minutes is appropriate for this purpose) after which the RLC protocol is applied (see Lichtenthaler et al. 2005). Examples of RLCs (Fig. 6a) illustrate the importance of the duration of light intervals. In addition to differences in the values determined for individual light intensities, there is also a difference in the shape of the curves (Fig. 6b). Pre- illumination at moderate light intensities ensures faster Fig. 6 Rapid light curves. a Example of RLCs (PAR vs. ETR) for which the duration of light intervals (20, 30, 60, 120 s) had been varied. Closed symbols represent the values measured after 30 min dark acclimation (without pre-illumination), and open symbols represent values measured following 30 min of dark acclimation and 5 min of pre-illumination at a moderate light intensity (100 lmol photons m-2 s-1). b The ETR/ETRmax ratio (ETRmax represents the maximum value for each curve) of measurements with light intervals of 120 and 20 s. c ETR values of experiments without pre- illumination (NO PI) and with 5 min of pre-illumination (5 min PI, 350 lmol photons m-2 s-1). Measurements were made on Citrus leaves using a Dual-PAM fluorometer (Walz, Germany) (Brestič and Zivčak, unpublished data) 136 Photosynth Res (2014) 122:121–158 123 induction. Thus, in pre-illuminated samples, a 30-s interval is sufficient to obtain appropriate values and shapes of the curves that are comparable to those measured with 2-min intervals (Fig. 6c). RLCs have frequently been used in studies dealing with plant stress (reviewed in Brestic and Zivcak 2013). The value of the RLC approach increases if a second technique, e.g., 820 nm or gas exchange measurements, is applied simultaneously, or if fluorescence-imaging measurements are also made. Question 19. What is the JIP test? The idea that the fluorescence rise OJIP contains a lot of information on the photosynthetic system is already quite old. OJIP transients have been compared to a bar code for photosynthesis (Tyystjärvi et al. 1999) and extensive attempts to simulate OJIP transients have been made (see Lazár and Schansker (2009) for a review of these efforts). In 1991, Strasser and Govindjee published an article on the recording of the full fluorescence rise kinetics OJIP between 40 ls and 1 s using a PEA instrument (see Strasser et al. 1995 for details). Four years later, Strasser and Strasser (1995) proposed a method to analyze these OJIP transients that was centered on the J-step [observed after 2–3 ms of strong illumination and equivalent to the I1 step of Schreiber (1986)], which they called the JIP test (see Fig. 7). The theoretical basis of the JIP test has been described in detail by Strasser et al. (2004). In the JIP test, OJIP transients are used to make a flux analysis, i.e., an analysis of the fate of photons absorbed by the PSII antennae (trapping, forward electron transport beyond QA and dis- sipation as heat). In the JIP test, the J-step is taken as the border between single and multiple turnovers. If we define multiple turnovers here as events related to electron transport beyond PSII, then this claim still remains valid. The JIP test depends strongly on the assumption that the FO-to-FM rise reflects the reduction of QA. The concept is internally consistent but the theoretical foundation of the interpretation of the parameters disappears the moment that this assumption turns out to be wrong (see Schansker et al. 2011, 2014 for a discussion of this point). An alternative approach to the interpretation of the OJIP transients is a classical physiological characterization of the various fea- tures of the fluorescence rise. In the JIP test, it is assumed that the relative position of the J-step between FO and FM (i.e., VJ, giving rise to the JIP-parameter 1 - VJ or WO) gives information on photo- synthetic electron transport beyond QA (e.g., Strasser et al. 1995, 2004). A physiological characterization of this fea- ture, on the other hand, suggests that the parameter VJ depends on the redox state of the PQ-pool in darkness (Tóth et al. 2007a) and, under certain stress conditions, may also be affected by other factors, possibly the extent of stacking of the thylakoid membranes. In this case, electron transport beyond QA means a slowdown of the re-oxidation of QA - as the PQ-pool becomes more reduced, and fewer PQ molecules are bound to the QB-site. Changes in WO may certainly point to stress. In the JIP test, the parameters FO and FM were suggested to be a measure for the absorption flux (i.e., the number of photons absorbed per unit of time) per cross section (Strasser et al. 1995, 2004). With respect to this interpre- tation, it may be noted that a characterization of the changes in the FO and FM levels as a function of the Chl content of leaves showed that they are nearly insensitive to changes in the leaf chlorophyll content as long as the antenna sizes of the RCs remain unaffected (Dinç et al. 2012). However, we note that this observation probably does not apply to dilute algal and thylakoid suspensions. Malkin (1966) and Murata et al. (1966) showed that the complementary area between the fluorescence transient and FM in the presence of DCMU is proportional to the pop- ulation of reduced QA molecules. In the JIP test, this principle is extended to the situation in the absence of DCMU, where the area between the fluorescence transient and FJ is assumed to equate one charge separation in all RCs, i.e., one electron transported, to which the total area above the OJIP transient can be normalized (see e.g., Strasser et al. 2004). Schansker et al. (2011, 2014) support and explain the relationship between the area above the OJIP transients (see Fig. 7) and the number of electrons that must be transported through the ETC before FM is reached. Fig. 7 Time points and parameters used in the JIP test. On the left hand side, the unnormalized F scale associated with the complemen- tary ‘‘Area’’ and on the right hand side, the V scale double normalized between O and P associated with the normalized area Sm (Goltsev, unpublished data) Photosynth Res (2014) 122:121–158 137 123 In the JIP test, it is assumed that the slope taken between FO and F150 ls is sensitive to a phenomenon called ‘‘con- nectivity,’’ i.e., the energy transfer between the antennae of several PSII RCs, whereas the slope taken between FO and F300 ls is insensitive to connectivity (Strasser and Stirbet 2001; and see Stirbet 2013 for a more in-depth discussion of connectivity in the absence of PSII inhibitors like DCMU). The performance index [PI(ABS)] was introduced as an attempt to catch three different aspects of the photosyn- thetic activity of PSII in a single parameter (see Clark et al. 2000 for an early application of this parameter). PI(ABS) is the product of a parameter sensitive to the effective antenna size, a parameter based on the primary quantum yield of PSII and a parameter sensitive to changes in the relative position of FJ. It is defined as: PI(ABS) ¼ FV FM VJ 4ðF270 ls�FOÞ FM�FO FV FM 1� FV FM 1� VJ VJ with VJ = (FJ - FO)/FM - FO). It is another JIP test parameter that has been shown to correlate with other stress parameters under a series of conditions (e.g., Clark et al. 2000; Misra et al. 2001a, b; Oukarroum et al. 2006). Physiological studies have further shown that the IP phase of the fluorescence rise is related to electron transport through PSI (Kautsky et al. 1960; Munday and Govindjee 1969; Schansker et al. 2005) and that the (relative) amplitude of the IP phase is linked to the PSI content of the leaf (Oukarroum et al. 2009; Ceppi et al. 2012). The JIP test approach remains a good and fast way to screen a large number of samples (Kalaji et al. 2011a, b). However, once parameters that correlate with certain features of a stress have been identified, it should not be blindly assumed that the interpretation of these parameters as given by the JIP test is correct (see also Stirbet and Govindjee 2011 for a discussion of this topic). In addition, it should be kept in mind that the JIP test depends strongly on normalizations which are very sensitive to the correctness of the deter- mined FO and FM values. For example, in the case of heat stress, it is not easy to determine the FO and FM values correctly (see Tóth et al. 2007b). Question 20. What kind of values may one expect for particular fluorescence parameters? The FV/FM values of plant species average approximately 0.83–0.84 in C3 plants under optimal conditions (Björkman and Demmig 1987; Pfündel 1998) and 0.78 in C4 plants (Pfündel 1998). Somewhat higher values have been described in certain broadleaved species. Lower values, on the other hand, are common in algae and lichens (see Trissl and Wilhelm 1993 for a discussion of these values). Stress conditions (e.g., photoinhibition) can significantly reduce these values (e.g., Björkman and Demmig 1987; Van Wijk and Krause 1991; Tyystjärvi and Aro 1996). Photochemical quenching qP, non-photochemical quenching defined as qN [= 1 - (FM 0 - FO 0)/(FM - FO)], and the PSII operating efficiency in the light (UPSII) can vary between 0 and 1 (see Question 14 for definitions of qP and UPSII). The theoretical range for the values of the non- photochemical quenching parameter NPQ [= FM/FM 0 - 1] is from zero to infinity, but in most cases, it gives values between 0 and approximately 10. However, NPQ values higher than 10 have been reported in bryophytes from sun- exposed habitats (Marschall and Proctor 2004; see Bus- chmann 1999 for a discussion and comparison of qN and NPQ). High UPSII values indicate that a large proportion of the light absorbed by the chlorophylls of the PSII antenna is converted into photochemical energy. At its upper limit, UPSII could reach a value of 1, which would mean that all absorbed energy is used for stable charge separations in PSIIs. From a practical point of view, this cannot be the case, due to the fundamental inefficiency of PSII (triplet formation, a small probability of fluorescence, and heat emission on each transfer of excitation energy between chlorophylls), and the contribution of fluorescence emitted by PSI has also an effect on the calculation (see Question 3). Therefore, UPSII can vary between zero and the FV/FM value, which in C3 plants is about 0.83–0.85, in C4 plants around 0.78 and in algae often below 0.7 (Pfündel 1998; Trissl and Wilhelm 1993). qP values near zero indicate that most of the PSII RCs are closed, and their QA is in the reduced state. Values near 1 indicate that QA is in the oxidized state, and almost all of the PSII centers are open for photochemistry. The non-photochemical quenching coefficients qN and NPQ are assumed to be zero in the dark-adapted state, because then FV 0 = FV and FM 0 = FM. However, in some cases, positive values of these coeffi- cients can also occur in darkness (see Question 17). In higher plants, the induction kinetics of non-photo- chemical quenching triggered by high light usually have a typical time dependence: they increase during the first minute of illumination due to initiation of electron trans- port and DpH formation preceding the activation of ATP synthase (e.g., Nilkens et al. 2010) and decrease again once the Calvin–Benson cycle is activated. This quenching is sensitive to the balance between the electron transport rate and its associated proton transfer toward the thylakoid lumen on the one hand and the rate of ATP synthesis and the associated release of protons from the thylakoid lumen on the other hand. This form of quenching (corresponding to qE quenching, see Question 15) relaxes quickly as soon as electron transport stops, e.g., as soon as the light is turned off (see e.g., Nilkens et al. 2010). Other processes 138 Photosynth Res (2014) 122:121–158 123 contributing to NPQ have slower induction kinetics (see Questions 2.3 and 15) whose induction (e.g., photoinhibi- tion) depends as well on light intensity. Higher non-pho- tochemical quenching values related to higher values of qE under steady state conditions suggest a stronger imbalance between photosynthetic electron transport and the utiliza- tion of NADPH (reflected by lower qP values) (see e.g., Walters and Horton 1993). Under continuous and/or extreme stress, non-photochemical quenching can attain low values. This may in part be due to a loss of RCs. Photoinhibited PSII RCs lose their variable fluorescence, and as a consequence, this variable fluorescence can then no longer be quenched, which means less NPQ (Schansker and Van Rensen 1999). Low values may also be caused by decreased rates of linear electron transport generating a smaller transthylakoid proton gradient or to an increased permeability of the membrane due to lipid peroxidation caused by oxygen radicals, which will also reduce the build up of a DpH over the membrane. Deviations from the NPQ induction kinetics have been described in some green algae, where the NPQ induction capacity varies strongly depending on the species (see e.g., Bonente et al. 2008). For example, in Ulva laetevirens, NPQ was induced with an early peak within the first minute of exposure to high light, followed by a decrease and a subsequent rise (Bonente et al. 2008). Question 21. Which assumptions are made when interpreting fluorescence transient measurements? Both the quenching analysis and the JIP test (see Questions 15 and 19 for a discussion) are based on assumptions that were commonly made in the 1990s (e.g., van Kooten and Snel 1990 for the quenching analysis, Strasser 1996 for the JIP test and see also Stirbet and Govindjee 2011 for a list of assumptions). The most important assumption is that the fluorescence increase from FO to FM reflects mainly the reduction of QA. This idea was first put forward by Duy- sens and Sweers (1963). However, this assumption was challenged almost from the beginning (see e.g., Delosme 1967). Delosme (1967) proposed the existence of two processes determining the fluorescence rise. His suggestion that the redox state of the PQ-pool could play a role (Delosme 1971) led to the idea that the QB-site occupancy state was the second factor (see Samson et al. 1999); an idea that was extended further by Schansker et al. (2011) who suggested that the QB-site occupancy state controlled the re-oxidation rate of QA - and who proposed on the basis of this idea that in the presence of QA - further excitations could induce conformational changes in the PSII RCs which would then cause an increase of the fluorescence yield. Considering the occupancy state idea, Schreiber (2002) proposed that the thermal phase might be explained by a reduction of the inactive branch of PSII. Vredenberg and co-workers (Vredenberg 2000; Vredenberg et al. 2006) developed another interpretation model, in which, in addition to QA -, the IP phase is determined by the electric field, and JI rise reflects an inactivation of PSII RCs (associated with proton transport over the membrane) in which Pheo- can accumulate. These alternative interpre- tations were challenged by Stirbet and Govindjee (2012). The first assumption that the FO-to-FM rise is a reflection of the reduction of QA implies that it should always be pos- sible to reach FM, since all QA can be reduced if the light intensity is high enough (i.e., when the excitation rate is much higher than re-oxidation rate of QA - by forward electron transport and/or the exchange of PQH2 for PQ at the QB-site). However, Schreiber (1986), Samson and Bruce (1996) and Schansker et al. (2006, 2008) showed in several ways that this is not the case. A second, related, assumption is that there are no changes in non-photochemical quenching during a satu- rating pulse. Finally, a third assumption is that the parameters FV/FM and UPSII are measures of the PSII quantum yield and that UPSII can be used to calculate the photosynthetic electron transport rate. For UPSII, this assumption has been partially verified experimentally, showing under several conditions a linear correlation between the calculated photosynthetic electron transport rate and the CO2 assimilation rate (Genty et al. 1989; Krall and Edwards 1992 and see Questions 29 and 30). We note that the meaning of the parameter FV/FM has not been derived experimentally but is based on an analysis of so- called competitive rate equations (fluorescence emission competes with other processes like heat emission and photosynthesis) for the FO and FM states (Kitajima and Butler 1975; Kramer et al. 2004). This analysis is correct as long as the fluorescence rise between FO and FM is determined by the reduction of QA only (see Schansker et al. 2014 for a discussion of this point). Question 22. Are there naturally occurring fluorescence quenchers other than QA? Another fluorescence quencher that has been described extensively is P680? (Butler 1972; Zankel 1973; Shinkarev and Govindjee 1993; Steffen et al. 2005). The short life- time of P680? keeps the population of this quencher low under most conditions. Simulation work has shown that under high light conditions, the highest concentration should occur around the J-step (Lazár 2003), which was supported by experimental observations (Schansker et al. 2011). However, P680? quenching does not affect the FO Photosynth Res (2014) 122:121–158 139 123 and FM levels. Oxidized PQ molecules can also quench fluorescence, but only in isolated thylakoids and in PSII- enriched membranes (Vernotte et al. 1979; Kurreck et al. 2000; Tóth et al. 2005a) and not in leaves (Tóth et al. 2005a). Other quenchers such as Car? and Chl? have been proposed and shown to play a role at temperatures below 100 K (Schweitzer and Brudvig 1997) in the case of ChlZ ?, an accessory chlorophyll molecule in the RC of PSII, or to have a very short lifetime at room temperature (Steffen et al. 2001) in the case of Car?. Neither of these quenchers seems to play a role in the fluorescence measurements discussed in this paper. Question 23. What is the difference between fluorescence emission spectra recorded at 77 K and those recorded at room temperature? In Question 2 Sect. 4, measurements of 77 K fluorescence emission spectra were introduced as a method to study PSII and PSI antennae. The recording of fluorescence emission spectra is much easier at room temperature. In this case, one dominant peak at *684 nm is recorded, which is attributed principally to fluorescence emission by the PSII- core complex (including the core antennae CP47 and CP43) and further a shoulder at 710–740 nm corresponding to several fluorescence emission sources—particularly PSI- LHCI and several minor PSII bands (Fig. 8) (Franck et al. 2005; Krausz et al. 2005; Pancaldi et al. 2002). When the temperature is lowered, the 684 nm band is replaced by two bands, peaking at 685 and 695 nm, respectively; bands that in first instance were shown to be associated with the PSII core (Gasanov et al. 1979; Rijgersberg et al. 1979). The 695 nm band is due to fluorescence emission from CP47, whereas the 685 nm has been associated with fluo- rescence emission by CP43 [(Nakatani et al. 1984; for spectroscopic analyses of CP47 and CP43: see Alfonso et al. 1994 (for both); van Dorssen et al. 1987 (CP47); Groot et al. 1999 (CP43)]. Srivastava et al. (1999) showed with an experiment on greening of peas how the 695 nm band increases in intensity as the PSII antenna size increases. In other words, despite CP47 being the source of the 695 nm emission, it is sensitive to the number of LHCII subunits bound to PSII. The relationship between the antenna size of PSII and the amplitude of the 695 nm band is further strengthened by the observation that chloroplast samples frozen in the presence of a DpH show a quenching of the 695 nm band (Krause et al. 1983). Based on a comparative study of photosynthetic mutants of Chla- mydomonas reinhardtii, a relationship between LHCII-PSII association and emission intensity at *695 nm has also been proposed at room temperature (Ferroni et al. 2011). To detect fluorescence emitted by LHCII itself as an individual peak at 680 nm, it is necessary to freeze the sample further to 4 K (see Govindjee 1995). However, a more or less distinct shoulder at 680 nm is often reported also at 77 K and attributed to the free LHCII trimers not linked with PSII in a stable association (Hemelrijk et al. 1992; Siffel and Braunova 1999; van der Weij-de Wit et al. 2007; Pantaleoni et al. 2009; Ferroni et al. 2013). At room temperature, the emission region around 680 nm, never visible as an individual peak in the spectrum, was also assigned to a contribution by free LHCII (Ferroni et al. 2011). Strasser and Butler (1976) showed that the strong band at 730 nm at 77 K is in part caused by energy transfer from PSII to PSI. Weis (1985) demonstrated that the absorption of PSII fluorescence emission by PSI can be reduced considerably using diluted ‘‘leaf powder’’ instead of whole leaf fragments. When using liquid samples, such as microalgae suspensions or isolated thylakoids, the PSI re-absorption of emitted light can be reduced by an ade- quate dilution of the sample. The re-absorption phenome- non also affects room temperature spectra, resulting in a relative increase in the emission at 710–740 nm and in a red shift of PSII emission (Franck et al. 2002). Room temperature fluorescence emission spectra are not frequently used for photosynthesis studies, because the spectral components are not as well characterized as the 77 K spectra are (Franck et al. 2002; Ferroni et al. 2011). However, methods have been developed to resolve at room temperature the contribution of PSII and PSI to Chl a fluorescence under FO, FM, and steady state conditions (Ft) (Franck et al. 2002, 2005). Figure 8 gives examples of two such applications. Room temperature fluorescence spectra have also been used to evaluate the response of photosynthetic organisms (microalgae and in higher plants) to some environmental stresses (Romanowska-Duda et al. 2005, 2010; Ferroni et al. 2007; Baldisserotto et al. 2010, 2012; Burling et al. 2011; Hunsche et al. 2011). Finally, such spectra have been used as well to characterize developmental aspects of the photosynthetic membrane (Pancaldi et al. 2002; Baldisserotto et al. 2005; Ferroni et al. 2009, 2013) and, as discussed in Question 25, to estimate leaf chlorophyll content. Question 24. Are the fluorescence rise kinetics sensitive to the chlorophyll content of the leaf? For dilute solutions of chlorophyll molecules, the measured fluorescence intensity is proportional to the quantum yield of fluorescence multiplied by the number of photons absorbed and the chlorophyll concentration (Lakowicz 2009). On this basis, one would expect that the fluores- cence intensity emitted by a leaf depends on the chloro- phyll content of that leaf. However, as described under 140 Photosynth Res (2014) 122:121–158 123 Question 4, the leaf is complex in optical terms, and it is difficult to predict if this physical law is really critical in determining the relationship between the chlorophyll con- tent of the leaf and the fluorescence emission. Several experimental studies have addressed this question. Hsu and Leu (2003) showed that two leaves placed on top of each other emitted more Chl a fluorescence than a single leaf. However, this is a quite artificial construct, and it can easily be shown that the outcome of the experiment strongly depends on the way the leaves were oriented (e.g., both adaxial sides up, or adaxial side up for the top leaf and the abaxial side for the bottom leaf) (Ceppi and Schansker, unpublished observations, 2008). Sušila et al. (2004) attempted to show an effect of chlorophyll content using thylakoid suspensions differing in their chlorophyll con- tent. Thylakoid suspensions are homogeneous in their properties, whereas under natural conditions, a change in the chlorophyll content will be accompanied by an adap- tation (change in antenna sizes and/or changes in PSI:PSII ratio) of the individual chloroplasts inside the leaf to their new light environment (see Question 4). To address the effect of changes in the chlorophyll content of a leaf on the measured fl